Use this convenient tool to view a sampling of arc flash hazard calculations and the impact of various system changes on arc flash energy levels and personal protective equipment ppe requirements. The available short circuit current at the intended work location. Ieee recommended practice for calculating shortcircuit. This excessive electric current potentially causes circuit damage, overheating, magnetic stress, arcing, fire or explosion.
When there is a short circuit the resistance becomes very small, and that means the current becomes very large. How do you calculate the maximum possible available fault. Transformer short circuit fault current calculator jcalc. Arc fault current calculations are based on voltage, bolted fault current, conductor gap distance, and other factors. The devices linked to are cable limiters and normally used to protect the legs of a parallel system to prevent a total outage when one of the parallel cables has a fault. In this situation, we assume cable length to be minimal and therefore neglect its. A bolted fault on the other hand is one that creates tremendous amounts of current and will sustain this current until the circuit is opened by some means. Electrical engineering should be consulted to obtain information on fault clearing times. Arc flash hazard analysis, custom label printing services. For example, a 75kva transformer with a 208y120 secondary and 5% impedance has a capacity of 208 amps on the secondary. Electrical formulas your electrical training center. Arc flash ansi vs comprehensive calculation method question. The simple answer is that the comprehensive short circuit method provides the. Consider short circuit analytic sca software capable of calculating accurate available fault currents from one source in its free trial version, and from multiple in commercial version.
Comply with ansi, nfpa 70e, nema, and nec standards and regulations. An ieee 1584 equation is used to calculate arcing fault current. For projects outside australia, powercad 5 supports iee, bs, cp5 and is india standards. The calculation is based on using the bolted three phase short circuit current. The bolted fault current used in the equation is obtained from the dc shortcircuit study. When calculating arc flash hazards throughout any facility, short circuit calculations are first performed. Home software fault analyses fault analyses fault analysis is an essential tool for the determination of shortcircuit currents that result from different fault phenomena, the estimation of fault locations, the identification of underrated equipment in electric power systems and the sizing of various system components. The formula is vir and can be shuffled in any any mathematical arrangement such as ivr, or rvi. A current that flows from one conductor to ground or to another conductor due to an abnormal connection between two conductors. However, in doing an arc flash hazard analysis it is recommended to do the arc. In this article ill be pulling some of the more important concepts. Electrical engineers use powertools to perform harmonic analysis, transient stability analysis, short circuit analysis, and to determine demand load, voltage drop, arcflash hazard analysis and protective device coordination. Calculatorstyle interface makes complex calculations easy to understand.
Figure 1 illustrates a simple singleline diagram that very well could be your basic service entrance for a commercial or industrial installation. Standard nfpa70e 2000 provides a short calculation method. Where e is the arc flash energy, e n is the normalized arc flash energy, i a is the arcing current, c f is the calculation factor, t is the duration of the arc, d is the distance from the arc to the person from ieee 1584, table 3, x is the distance xfactor, k 1 and k 2 are constants, and g is the conductor air gap. Arc fault currents can be determined by computer software like etap, skm. The arc flash software enables calculations for both of the above considered cases. During arc flash, temperatures of 20,000 o c for several metres around equipment can exist, resulting in severe burn injuries. Ieee 1584 arc flash calculations electrical diagnostic surveys. Fault current calculations are based simply on the theory of ohms law. Ieee 1584 presents two formulas for calculating arc fault currents, one for use with 0. In addition, tleads must be potted and end plates must be fitted with specific tolerances to contain an explosion. Arcfault is fully integrated with star protective device coordination module utilizing timecurrent characteristic tcc curves and short circuit calculations for arcing fault hazard evaluation. Dc demo the dc arc flash in ptw utilizes the maximum power method annex d, d. Ansi shortcircuit short circuit calculation software. Arc flash working in the vicinity of electrical equipment poses an hazard.
This tool uses methods that have been shown to result in conservative estimates of fault current, which should result in conservative estimates of arc incident energy if appropriate arc fault clearing times are used. Dc arc flash in an enclosurebox if the dc arc flash occurs in an equipment enclosure, the energy will be directed out of the boxs open end. Going to basics, maximum fault current iaei magazine. A shortcircuit condition that assumes zero impedance exists at the point of the fault. Perform device duty calculations using etaps short circuit analysis software which allows you to determine fault currents and automatically compare these values against manufacturer short circuit current ratings. Arc flash software arc flash analysis arc flash calculation arc. See our ieee 1584 page for more information on arc flash calculations or arcing fault current. Input all data from the singleline diagrams and the data collection effort into a short circuit program.
The arc flash calculation software module also produces professional reports and high quality arc flash hazard labels at a press of a button. Example arcing shortcircuit current calculation a 480v panel has an available bolted threephase fault current of 30,000 amperes a based on a conventional shortcircuit study. For this reason there is interest by many, these days, in a temporary second group of setting which reduce the. Automatically determine the trip times from the protective device settings. Introduction to short circuit analysis course content a short circuit is a lowresistance connection established by accident or intention between two points in an electric circuit. The new ieee1584 guide for performing arcflash calculations. The incident energy result is expected to be conservative. In examining either of these equations, it becomes clear that the energy of an arc flash is dependent upon the length of the flash, the available shortcircuit current or bolted fault current, and inversely and exponentially related to ones distance from the origin of the flash. Powercad 5 is australias leading electrical engineering design software solution for consulting engineers. Easypower ansi shortcircuit software delivers intelligent, easytouse tools to. The calculated arcing fault current associated with the available short circuit current. Since 1972, skm has been the software of choice of over 45,000 engineers worldwide.
Arcad service includes online resources, software programs and mobile apps that allow electricians, contractors, engineers, facility managers to perform fault current calculations, determine incident energy, arc flash protection boundary, level of personal protection equipment ppe, and to create customized arc flash warning labels meeting. The fact that arcing ground faults may be very low and may persist for a long time is well known in the industry, and has been the subject of many ieee articles dating back to the 50s, 60s and 70s. He was a journeyman electrician, master electrician, and electrical contractor. The arc flash calculation result is based on several factors. Calculation of arc flash incident energy and protection boundary in accordance with iee std. In addition to electric shock hazard, fault currents passing through air causes arc flash.
Makes pointtopoint fault current calculations easy. Shortcircuitanalytic sca software performs available fault currents calculations in threephase electric power systems you are working with. In arc flash calculations, a conservative fault current doesnt always result in a. The arcing current can then be used to find the protective device opening time and incident energy by using the threephase equations provided in ieee 1584 2nd edition and implemented in arc flash analytic version 6. For this calculation, the dc arc models paper refers to another technical paper, simple improved equations for arc flash hazard analysis, ieee electrical safety forum, aug. You cant use current limiting fuses to reduce the available fault current at the meter can. Automatically determine the arcing fault clearing time. A service equipment must be marked with the maximum available fault current and date of calculation b if fault current increases due to system modification, the marking must be updated. A bolted fault current is the maximum available fault current at some point in the electrical system. The basics of arc flash fact sheet v2 ge industrial. You will find sheet with very nice example already fulfilled. Well first use the concept of admittance to calculate the fault current in the system shown in fig.
An arc flash occurs during a fault, or short circuit condition, which passes. The arcing shortcircuit current will be calculated. Powercad5 electrical engineering design software, cable. A fault current flowing through an electric arc plasma. The arc flash analysis module also includes comprehensive. Cooper bussmann software programs are available to help you save time in determining a variety of product data and technical information that will help you with design applications and determining electrical values. The predicted threephase arcing current must be found to determine the operating time for protective devices. Easily calculate available fault current anytime, anywhere. An arcing fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground. Powercad 5 includes design methology and compliance checking with australian and new zealand standards asnzs 3000. Initially, they were used to quickly solve the nonlinear load flow problem and calculate short circuit currents, but their use has been extended to many other areas such as power system stability, protection and coordination, contingency reliability, economic modelling, etc. Arc flash calculation software and short circuit analysis. Lets work through a few simple examples to show how you can quickly and easily calculate fault currents. Arc flash calculator easypower arc flash analysis software.
The magnitude of an arcing fault will be less than a bolted fault due to the arc impedance. Overstressed device alarms are displayed on the oneline diagram and included in short circuit analyzer and study reports. During an arcing fault, the arc has resistance, which causes the arcing shortcircuit current to be smaller than the bolted shortcircuit current. It may be a precursor to a short circuit or ground fault, but in and of itself, an arc fault may not shut down either a gfci or a circuit breaker.
Ieee 1584ieee guide for performing arc flash hazard calculations provides two sets of equations for calculating the arcing shortcircuit current. John sokolik and it represents an easy way to calculate fault current by entering few values in indicated fields. Tsewg tp15 arc flash calculations and detailed arc flash. Fc 2 mobile app quickly delivers fault current calculations in the palm of your hand. Fault current calculations electrical diagnostic surveys. Short circuit and arc flash calculator electrical engineering portal. Follow the calculation methods outlined in the latest release of ieee 1584 and nfpa 70e. The arc flash analysis program is a completely integrated module that solves multiple scenarios to determine worstcase arc flash energy levels.
Contain an extensive library consisting of thousands of protective devices validated by electrical engineers. Electrical calculation tools are based upon schneider electric ecodial electrical network calculation wellknown software. No download needed, direct access from your web browser. The same tests were performed on a previously developed fault locator algorithm that includes a squarewave power frequency approximation of the fault. A dangerous condition associated with the release of energy caused by an electric arc. The fault current flowing through an electrical arc plasma, also called fault current and arc current. Everything you need to know about calculating fault currents, you learned in circuits 101, trigonometry, and basic math classes.
Ibf bolted fault current ka ia arc current ka t arcing time seconds d working distance from arc inches db separation of the flash protection boundary from the arcing point inches nfpa 70e tables flash protection boundary nfpa 70e presents a simple method of assessing flash protection boundary. The point of contact between the rod and the metal surfaces gets heated to the melting point, fusing a part of the rod and both surfaces into a single piece. Fault current calculations are based on ohms law in which the current i equals the voltage v divided by the resistance r. Mike holt worked his way up through the electrical trade from apprentice electrician through electrical contractor, to become one of the most recognized experts in the world as it relates to electrical power installations. And if this method has a higher value, shouldnt the arc flash model being using it. This excel file combines arc flash equations from a proposal to nfpa 70e2003 with simplified equations to calculate available fault current. Ieee 1584 arc flash calculations electrical diagnostic.
An arcing fault can release tremendous amounts of concentrated radiant energy at the point of the arcing in a small fraction of a second resulting in extremely. This calculation determined the bolted fault current at a location which is then used to derive arcing fault current. The programs take into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, motors and generators. The current that would flow if each pole of the breaking device under consideration were replaced by a link of negligible impedance without any change of the circuit or the supply. Why is the comprehensive short circuit study dapper used in arc. Simply enter the bolted fault current, choose a current limiting fuse from the dropdown menu, and select calculate. Skm is the leader in power systems analysis and design software for fault calculations, load flow, coordination, arc flash hazards, motor starting, transient stability, reliability, harmonics, grounding, cable pulling, and more.
The threephase ungrounded bolted fault is usually mistakenly assumed to be the maximum fault current when in all actuality the single phasetoground fault often produces a greater fault current under certain circumstances. Bussmann series fc2 calculatorfault current calculation. Verify equipment duty ratings instantly on the oneline. Short circuit current calculations cooper industries. Ieee 1584 revisions significant changes on the way for arc. Arc flash calculator free electrical safety software. However, this assumption is not applicable for motor startup calculations where the fault level is used as an input to the motor startup calculation.
I seem to recall motors installed in class i division 1 locations need to be explosion proof with a service factor of no greater than 1. Arcad service includes online resources, software programs and mobile apps that allow electricians, contractors, engineers, facility. This removes the arcing impedance that is normally a part of the circuit and yields a maximum available fault current. Theres another impedance tolerance option in the software that can be used. Modelbased general arcing fault detection in medium voltage distribution system v1. Mar 07, 2019 the 2002 version of ieee 1584 recognized that there was some statistical deviation in the equations, therefore the worstcase incident energy was determined based upon the clearing time at 100% of the arcing current compared to that at 85% of the arcing current. The first step to ensure that system protective devices have the prop. Arcfault contains customizable calculation methods and equations allowing the user to account for future research on arc fault physical behavior. Short circuit fault current software electric arc arc flash. The infinite bus short circuit calculation method is a simple way to determine the maximum fault current based on transformer nameplate data.
What is the difference between the ansi and comprehensive calculation that leads ansi to be so much higher. For instance, if a linetoline fault occurs 50 feet from a transformer, then 100 feet of cable impedance must be included in the calculation. Short circuit analytic sca software and mobile apps perform available short circuit fault current calculations in threephase electric power systems you are working with. Enter the bolted, threephase shortcircuit current i bf. The calculations on the following pages illustrate 1o fault calculations on a singlephase transformer system. The peak let through with an infinite source worst case scenario would have 208 0. Most of these programs are available to you at no cost through this web site or as a down load to your pc. Arc flash software to calculate incident energy, identify high risk areas, and analyze.
The current in a pole of a switching device at the instant of the arc initiation. Short circuit current calculations electrical diagnostic. Therefore, the current literature is lacking calculations of arc flash hazard in dc systems. Before starting fault current calculation, you will have to choose between step 1a and step 1b which are explained below. Ieee 1584 standard does not discuss arc flash hazard calculations in the dc systems. An arc flash calculator can be used to determine incident heat energy at a particular distance and the category of ppe required. Explosion proof motors vs xp motors and nec requirements for.
That is the fault current value that is used to determine the clearing time of the overcurrent protective device ahead of the potential arc fault location. The necessary calculation steps are very similar to calculations in ac systems, however. Note that this assumption will give the worse case fault level on the secondary side of the transformer, which is sufficient for sizing of equipment according to fault rating. Short circuit current calculations cooper bussmann.
The lowest arcing current may be from a ground fault. Now the calculation is tightened up and an arcing current variation factor is. Calculate the voltage drop of a defined cable and check the maximum length. Etap arcfault analysis software is used for performing arc flash analysis in. The current that flows through an arcing fault is usually significantly less than the bolted fault current, due to greater resistance. It also remains a mystery how appropriate arc fault clearing times can be chosen based on conservative estimates of fault current. Many faults start out as intermittent, arcing faults with relatively low magnitude currents. Edmund elizalde eyp mission critical facilities, inc. This standard defines the accepted water corporation practices for arc flash incident energy assessments, arc rated personal protective equipment, warning label specifications and design safety to reduce arc flash risk for hv and lv electrical switchboards. Short circuit analytic sca software and mobile apps perform available short circuit fault current calculations in threephase electric power systems you are. Admittance is a measure of how easily a circuit or device will allow a current to flow.
An arc fault, as mentioned above, is when loose wire connections or corroded wires cause sparking or arcing, which may create heat and the potential for electrical fires. Ohms law is a simple formula relationship of voltage, current, and resistance. There is not an easy way to limit the current at the meters on that system. A timecurrent curve approach to arcflash hazard analysis. The arcing current can then be used to find the protective device opening time and incident energy by using the threephase equations provided in ieee 1584 2nd edition and implemented in arc flash analytic v6. Arcflash hazard calculations standard 1584 20021 arcflash hazard. Plant engineering ieee 1584 2018 changes offer a robust. Minimum and maximum arcing short circuit currents are calculated using broad.